Structures Rules
Below is the list of rules implemented by C3DRENESG for the structures.
To edit these values in your project, use the command
CEDITRULES.
If you've used the previous version (version C3DRENESG4 C3DRENESG2 or 2736 or
above), use the command
UPDATERULES, so that the rules are converted to this new version.
-
Section - Sets the limits of geometry (s) pipe (s) arriving (m) or leaves the structure
Accepts:
-
Maximum Height - Limits the maximum height of the largest pipe that reaches the structure
-
Minimum Height - Limits the minimum height of the largest pipe that reaches the structure
-
Maximum width - Limits the maximum width of the largest pipe that reaches the structure
-
Minimum Width - Limits the minimum width of the largest pipe that reaches the structure
-
Number of inline pipes
-
Flow - Limits the input flow in culverts, inlets, sewer manholes
Accepts:
-
Pipe drop - Limits the difference between the share of lower generating internal pipes that reach the elevation structure and bottom of
Accepts:
-
Maximum pipe drop
-
Minimum pipe drop - In some cases it is desirable to have box
accumulation within the manhole.
In these cases, use the minimum step
together with the sump described below least
-
Sump - Limits the difference between the elevation of the lower generatrix of the pipe coming out of the structure and background of this elevation
Accepts:
-
Minimum Sump
-
Maximum
Sump
The shoulder serves to create a box sludge accumulation within the structure.
See the figure:
See also pipes rules