C3DCalc
This command calls the calculation worksheet.
But before it checks the consistency of the network , which must satisfy the following rules:
-
All structures and pipes should be in Parts List
(not necessary, but is a good ideia)
-
All pipes must have a structure connected upstream and downstream
-
All structures must have only one pipe coming out except those that are at the discharge point,
they will not have the outlet pipe
.
-
It should be discharge points in the network, that is, a structure that has no outlet pipe
-
All structures must be have at least one pipe connected
For example, the network complies with these rules below:
Note: that all nodes have a structure.
The flow is directed from left to right.
Note:
At launch you to draw the pipes from upstream to downstream with "Flow method" type "Start to End".
But the network does not pass the consistency test.
If the network does not pass this test, you will be informed which the error that prevented it.
By default, the network has no definition of network type.
They are only networks
drainage when associating an area of contribution to a structure.
Or when the network has ever been calculated.
If this definition of type cannot be verified, the program will ask which network type on the command line.
Tips:
-
Implement Rules to make available to the
C3DRENESG
-
Read operation sequence proper release before using
this command