For the dimensioning of manholes according to circular nº 5 "Bureau of Public Roads", when considering exit control, the dam calculation requires the Ke coefficient:
Design Entrance | Ke |
---|---|
Projecting from fill, Socket end of pipe (groove-end) | 0.2 |
Projecting from fill, Square cut end | 0.5 |
Headwall or headwall and wingwalls, Socket end of pipe (groove-end) | 0.2 |
Headwall or headwall and wingwalls, Square-edge | 0.5 |
Rounded (R = 1/2 D) | 0.2 |
Mitered to conform to fill slope | 0.7 |
End-Section conforming to fill slope | 0.5 |
Beveled edges, 33.7º or 45º bevels | 0.2 |
Side- or slope-tapered inlet | 0.2 |
Design Entrance | Ke |
---|---|
Projecting from fill (no headwall) | 0.9 |
Headwall or headwall and wingwalls square-edge | 0.5 |
Mitered to conform to fill slope, paved or unpaved slope | 0.7 |
End-Section conforming to fill slope | 0.5 |
Beveled edges, 33.7º or 45º bevels | 0.2 |
Side- or slope-tapered inlet | 0.2 |
Design Entrance | Ke |
---|---|
Headwall parallel to embankment (no wingwalls), Square-edged on 3 edges | 0.5 |
Headwall parallel to embankment (no wingwalls), Rounded on 3 edges to radius of D/12 or B/12 or beveled edges on 3 sides | 0.2 |
Wingwalls at 30º to 75º to barrel, Square-edged at crown | 0.4 |
Wingwalls at 30º to 75º to barrel, Crown edge rounded to radius of D/12 or beveled top edge | 0.2 |
Wingwalls at 10º to 25º to barrel, Square-edged at crown | 0.5 |
Wingwalls parallel (extension of sides), Square-edged at crown | 0.7 |
Wingwalls parallel (extension of sides), Side- or slope-tapered inlet | 0.4 |