EDITAFUROS
Manages the list of boreholes registered in the current drawing.
When calling the command, the following screen is displayed:
In this screen, at the top, we have the buttons:
-
Import - To import from M$ Excel the boreholes, which will be saved inside the DWG.
The file will be requested.
You will also be asked what to do in case of duplicate boreholes, or what to do with the list that already exists in the DWG
-
Export - To export to M$ Excel the boreholes
-
Styles - Shows the edit command screen ed drill styles
-
Expand columns - Resize columns to better represent tables
-
Layout - Changes the layout of the program
-
Freeze Panels - Freeze / unfreeze panels in current cell
-
Update - enables or disables updating of drill boreholes
In the table, we see the following columns:
-
Name - Hole name Unique identifier, should not be repeated
-
Style - Controls the style of the bore in plan and profile
-
Type - type of drill borehole, can be:
-
SM - mixed poll
-
SR - rotary drilling
-
ST - piercer
-
SP - percussion well
-
PI - inspection well
-
PT - piercer-well
-
X - ordinate X of the borehole location
-
Y - ordinate Y of the borehole location
-
Depth - depth reached by the borehole
-
Has NA - indicates if water level has been determined
-
NA - if the water level is determined, inform the depth at which it occurs
-
Impenetrable - indicates whether the borehole hits the impenetrable
It does not apply to boreholes of type SM or SR
-
Description - any extra description that borehole needs
-
Alignment - Reference alignment to calculate station and offset
-
Surface - Reference surface to calculate borehole elevation
-
Recovery
It only applies to boreholes of type SM and SR
-
Initial Depth - numeric value with the initial depth
-
Final Depth - numeric value with final depth
-
Percentage - numeric value of the recovery percentage (without the% symbol)
-
NSPT
-
Depth - given in meters
-
Number of hits - integer
-
Prof.
< 30 cm - When not reached the depth of 30cm in the value of the NSPT, indicates the depth reached, in centimeters
-
Layers
-
Initial Depth - numeric value with the initial depth
-
Final Depth - numeric value with final depth
-
Description - text with layer description
-
Collections
-
Initial Depth - numeric value with the initial depth
-
Final Depth - numeric value with final depth
-
HRB - text with rating
-
CBR - numeric value that indicates the value of the CBR (without the % symbol)
-
Expansion - numeric value that indicates Expansion value (without symbol%)
After editing the table, click the OK button, so that the data is saved in the DWG
See also: